ULTRAMETER III 9P™
AHL Titration Kit
AHL Titration Kit
Since 1957, the Myron L Company has designed and manufactured highly accurate and reliable analytical instruments for a wide variety of demanding applications. Thousands of professionals around the world rely on the performance of our instruments every day. Uses range from boiler water testing to ultrapure water control to medical instruments for artificial kidney machines. We are proud of the trust our handheld instruments and monitor/controllers have earned. Some of our instruments have been in continuous use for over 40 years. Our latest digital handheld, the Ultrameter III 9P, is based on the tried and tested design of the Ultrameter II. The 9P adds the ability to perform in-cell alkalinity and hardness titrations either as stand-alone measurements or as part of an LSI calculation. Alkalinity, hardness, pH and temperature values can be manipulated in the LSI calculator to predict the effect of changes on water balance. Measurements are extremely accurate. And the 9P is simple to operate and maintain.
NEW! FCE FAC Readings
The Myron L Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user
the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from
the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L
Company FCE function measures the real, unaltered chemistry of source water, including moment-to-moment changes in that chemistry.Alkalinity, Hardness & LSI Titration Kit.
A hard foam-lined
case organizes and protects all
contents: The 9P; 9P cell extender;
required reagents for in-cell alkalinity,
hardness and LSI titrations; standard
calibration solutions for all parameters;
storage solution to protect the pH/
ORP sensor; and pipette for precision
dispensing with additional tips. Sensors
are internal and included.
The 9P is also capable of wireless
communication with the bluDock™
option installed. The bluDock uses
Bluetooth® technology to transfer data
wirelessly to your personal computer
and comes with user-intuitive software
that makes it easy to analyze saved
water sample data. 9P Titration Kit
includes 9P; cell extender;
100µL pipette; 12 tips; 3
buffers (pH 4, 7, and 10);
pH/ORP Sensor Storage
Solution; ORP Conditioner
Solution; titration reagents and
standards H2SO4-1, HCl-3, NAOH,
EDTA-LC, EDTA-HC, Alkalinity Standard 100 and
Hardness Standard 200; standard solutions KCI-7000 and 442-3000.
All bottles are 2 oz/59 ml. model: 9PTK9PTK AHL Titration Kit can be ordered with the bluDock Accessory Package, as well. kit with bludock: 9PTK-BD
In-cell titration functions
The Ultrameter III adds the ability
to perform in-cell conductometric
titrations that provides a convenient
way to determine alkalinity, hardness
and LSI in the field. This eliminates the
need to collect and transport samples
to another location for analysis. User
intuitive display prompts guide you
through titration procedures from
start to finish. All required reagents
and equipment are included in the 9P
titration kit. Hardness unit conversion
The Hardness titration, LSI Titration
and LSI Calculator functions allow you
to set the hardness unit preference to
either grains of hardness or ppm
CaCO3. Accuracy you can trust
Like the Ultrameter II, the Ultrameter III delivers exceptional
accuracy of ±1% of reading (±.1%
at calibration point). This high level
of accuracy is achieved through
advanced four-electrode conductivity
cell technology, a powerful
microprocessor, proprietary circuit
design and conversion algorithms for
three of the most common solution
types, as well as a unique pH/ORP
sensor. With displayed values of up to
9999, the full four-digit LCD ensures
resolution levels never before possible
in such affordable instruments.
For accuracy in diverse applications,
Ultrameter III allows you to select
from 3 solution modes that model the
behavior of the most common solution
types: KCl, NaCl and 442™ Natural
Water. Additionally, the Ultrameter III
features a user adjustable conductivity/
TDS conversion ratio for greater
accuracy when measuring solutions
not contained in the microprocessor.
The Ultrameter III is factory calibrated with NIST traceable solutions.
Certification of traceability and NIST traceable standard solutions can be purchased as accessories for definitive calibration.
Innovative Engineering
The Ultrameter III is a prime example
of how high-tech engineering can
greatly simplify and streamline a task.
Whether in the lab, industrial plant, or
in a remote field location, electrometric
measurements are accomplished in 3
easy steps:1. Fill the cell cup
2. Push a parameter key
3. Take the reading
Temperature compensation and range selection are both rapid and automatic. User adjustable temperature compensation (up to 9.99%/°C) which can also be disabled for applications requiring non-compensated readings. Digital results display instantly. Measurement is continuous, displaying real-time readings rather than a static snapshot of the solution.
Easy to calibrate
All calibrations are quickly
accomplished by pressing the ▲ or ▼
keys to agree with our NIST traceable
Standard Solution. When calibration
is necessary, display prompts simplify
pH calibration and make sure the
correct buffer is being used. Plus,
all parameters (excluding factory set
temperature) have an internal
electronic setting that can be used for
field calibration and as a check on pH/
ORP sensor life. Wireless Benefits
The optional bluDock™ accessory
package is an integrated data solution
for your record keeping requirements,
eliminating the need for additional
hardware, wires and hassle. Because
the user never touches the data, there
is little opportunity for data tampering
and human error. bluDock software
has an easy to use interface with user
intuitive functions for storing, sorting
and exporting data. 
Range of readings
Features & Benefits
Hardness, LSI, pH, ORP/Free Chlorine, Temperature
Accessories, Replacement items and Solutions
models: UCC (Blue); UCCDT (Desert Tan)
Calibration Solutions are required for alkalinity, hardness and LSI titrations. models: Reagents H2SO4-1, HCL-3, NAOH, EDTA-LC and EDTA-HC available in 2 oz/59 ml and 1 qt/1 L. Alkalinity Standard 100 and Hardness Standard 200 available in 2 oz/59 ml, 1 qt/1 L, and 1 gal/3,8 L.
model: FVMP-100
model: PTIP100-48
model: BLUDOCK