750 series II CONDUCTIVITY/TDS MONITOR/CONTROLLERS
Click here for detailed image of the 750 II conductivity

 

BENEFITS

  • Affordable

  • Ease of Operation

  • Low Maintenance

  • Ensures Product Quality

The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by “field proven” electronics, including automatic DC offset compensation and highly accurate drive voltage.

 

Since temperature compensation is at the heart of accurate water measurement, all Myron L Monitor/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models corrected to 25°C. The TC may be disabled to conform with USP requirements.

 

Built-in electronic calibration allows for fast quality checks without standard solutions. (Note: for maximum system accuracy standard solutions are recommended).

 

A push-to-test button makes setpoint checks easy, while the internal alarm set discourages unauthorized adjustments.

 

Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings.

 

All 750 Series II models feature an IP65/ NEMA 4X water resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface mounting.

 

Additional options include a 3 Sensor Input Switch and/or a 3 Range Switch and a Remote Alarm™ model RA.

 

CUSTOM & OEM MODELS AVAILABLE

 

 

SENSORS — CS51LC, CS51 and CS52

These reliable sensors feature an integral temperature sensor to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene bushing is modular for easy inexpensive replacement. Several alternatives for the metal portion of the sensor are available, depending on the demands of the application.

CS51LC sensors (0.1 constant) are used for 5 and below.

CS51 sensors (1.0 constant) are used between 0-10 and 0-20,000.

CS52 sensors (10.0 constant) are used above 20,000.

Low cost, low temperature, low pressure sensors available upon request. See 750II Sensor Selection Guide.

 

Applications

Reverse Osmosis
Process Control
Seawater Desalination
Waste Treatment
Food Processing
Plating
Power Plants
Laboratories
Printing
Aquaculture
Agriculture
Environmental Studies
Medical
Boilers (250 psi @ 205°C)
Cooling Towers
 
 
 
 
 
 
 
 
 
 

FEATURES

34 Conductivity/TDS ranges: 0- 1 microsiemens/ppm to 0-200
millisiemens/ppt
Choice of 3½ digit display or analog meter
Automatic temperature compensation to 25°C
Isolated 0-10 VDC Recorder Output standard
IP65/NEMA 4X water resistant and corrosion proof enclosure
Built-in electronic calibration
Single set point/alarm standard
Adjustable setpoint hysteresis 
Solid State 24 VDC  Output
10 amp relay operates on choice of increasing or decreasing reading
LEDs show "above/below" Alarm/control status
Push-to-test set point check
Internal set point discourages unauthorized adjustment
Selectable 115/230 VAC
CE Certified
Reliable, easily installed sensors

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SENSOR SPECIFICATIONS

Temperature Compensation:  Integral thermistors provide automatic TC to 25ºC between 0-100ºC/32-212ºF.

Pressure /Temperature Limits: CS51: 100 psi / 690 kPa @ 100°C/212°F. 250 psig @ 205°C, Models CS40 and CS41 sensors available on special order.

Bushing: Modular Polypropylene threaded 3/4” NPT. 1/2” PVDF or 316 stainless steel fittings available as option.

Cable: Shielded 10 ft./3 meters standard 25 and 100 ft./ 8 and 30 meter lengths available. 100 ft./30 meter is maximum recommended.

Dimensions: CS51: Metal portion 30 L x 13 Dia. mm/ 1.2 L x .5 Dia. in.

 

 

Additional Information

750 Series II Data Sheet
(includes specs, options and order info)

click here: PDF

Price List click here: PDF
Sensor Price List click here: PDF

750II Sensor Selection Guide 

click here: PDF

750II Range Selection Guide  click here: PDF
Conductivity Sensor - CSA Series click here: PDF
Conductivity/Resistivity Sensor #CS40 click here: PDF
Conductivity/Resistivity Sensor #CS41 click here: PDF
Conductivity Sensor #CS50 & 60 click here: PDF
Conductivity Sensor #CS51 click here: PDF
Conductivity Sensor #CS52 click here: PDF
Sanitec Fitting Sensor Option click here: PDF

Operation Manual

click here: PDF

 

Limited Warranty
All Myron L Monitor/controllers and Sensors have a Two (2) Year Limited Warranty. If any Monitor/controller or sensor fails to function normally, return the unit to the factory prepaid. If, in the opinion of the factory, failure was due to materials or workmanship, repair or replacement will be made without charge.
A reasonable service charge will be made for diagnosis or repairs due to normal wear, abuse or tampering. Warranty is limited to the repair or replacement of monitor/controller or sensor only. The Myron L Company assumes no other responsibility or liability.

 

     